--- title: "Parameters - Test and Performance Suite Guide - Lasernet FO Connector" slug: "parameters-test-and-performance-suite" description: "The Test and Performance Suite Parameters can be accessed by navigating to Lasernet > Test and performance suite > Parameters." updated: 2026-03-03T14:26:44Z published: 2026-03-03T14:26:44Z canonical: "kb.lasernetgroup.com/parameters-test-and-performance-suite" --- > ## Documentation Index > Fetch the complete documentation index at: https://kb.lasernetgroup.com/llms.txt > Use this file to discover all available pages before exploring further. # Parameters The Test and Performance Suite Parameters can be accessed by navigating to **Lasernet** > **Test and performance suite** > **Parameters**. The settings in this form are split into three tabs: - **General** - **License terms** - **Version** ## General Two settings are available within the **General** tab: - **Ignore usage data during test recording and playback** - **Disable tabbed print settings form design** ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (60)(1).png) ### Ignore Usage Data during Test Recording and Playback ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (61)(1).png) This parameter is used with the Task recorder and UX testing functionality. Refer to the [Task recorder and UX testing](/v1/docs/ux-testing) section of this guide for more information. This parameter can be used to ignore the usage data during a Task recorder recording and test run. This can be used to ensure that a user’s usage data does not affect a task recording and test run. For example, if a user were to clear their usage data, they would have the **Print confirmation** setting on the **Confirm sales order** dialog set to **No**. This means that the options within the **Printer setup** drop-down list would be greyed out. These options cannot be clicked until **Print confirmation** is set to **Yes**: ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (62)(2).png) If **Ignore usage data during test recording and playback** is set to **Yes**, there will be no issue when a task recording and UX test are run, since the **Print confirmation** will be set to **No** for the task recording and test run. However, if **Ignore usage data during test recording and playback** is set to **No**, you may come across the following problem: Scenario: A user is creating a task recording. The user’s usage data has defaulted the **Print confirmation** to **Yes**, so no change is made, and the Task recorder does not record the setting. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (63)(2).png) Setting **Print confirmation** to **Yes** allows a user to click the **Confirmation** button. As shown in the screenshot, the Task recorder has not recorded setting **Print confirmation** to **Yes**, as the user’s usage data already defaulted the field to **Yes**. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (64)(3).png) The task recording is saved, and a UX test is created based on the task recording. After the task recording was made, the user confirmed a sales order and changed the **Print confirmation** to **No**. The user’s usage data has now been updated, so **Print confirmation** is set to **No** when a sales order is confirmed in the future. The same user runs a UX test that follows the steps in the task recording. The user’s usage data has set the **Print confirmation** to **No**. This causes the UX test to fail at step 4 because this field needs to be set to Yes to complete the remaining steps in the UX test: ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (65)(2).png) This shows that setting **Ignore usage data during test recording and playback** to **Yes** can remove errors related to usage data differences between when a task recording is recorded and when a UX test is run. If this functionality is to be used, it is advised that **Ignore usage data during test recording and playback** is set to **Yes** before the task recording is recorded to ensure the task recording and UX test do not use usage data. ### Disable Tabbed Print Settings Form Design ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (66)(3).png) Lasernet FO Connector uses a 'tabbed form' (table of contents) by default for the **Print destination settings** form. This is because a tabbed form design is required to ensure a UX test selects the correct print destination in the **Print destinations settings** form without triggering an error. The regular form can be activated by setting the **Disable tabbed print settings form design** to **Yes**. In this example, the regular form has caused a playback error in the UX test: ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (67)(3).png) ## License Terms The **License code** field provides a location for a Test and Performance Suite **License code** to be entered. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image-GTR8ZXMV.png) > [!NOTE] > Note > > This licence code is different to Lasernet FO Connector licence code which is entered in **Lasernet** > **Setup** > **Parameters**. The **Expiration date** field is used to indicate the expiration date for the Test and Performance Suite licence. The **Users field** displays the maximum number of **Operations** **users** allowed for this Test and Performance Suite licence. The Test and Performance Suite licence is linked to the number of Operations users in the Dynamics 365 FO environment. The **Required user count in license** is the number of **Operations users** in the Dynamics 365 FO environment. The number of **Operations users** can be found by: 1. Navigating to **System administration** > **Inquiries** > **License** > **User License Counts**. 2. In the **Date for Named User License User Count** field, specify the current date. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (69)(3).png) 1. The number of **Operations users** is shown next to the **Operations Access License Type** once the report has run. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (70)(2).png) A warning will be shown when the number of days indicated by the **Expiration warning** field is reached before the license expiration date. Specify **-1** or less to disable warnings. The default **User count expiration warning** is 30 days. This means a warning message is shown if the **Named user license count reports processing** batch task has not been executed within 30 days. The number of days before a warning is displayed can be changed by changing the value in the **User count expiration warning** field. Specify **-1** or less to disable warnings. ## Version This section displays the version information for Lasernet FO Connector in the Dynamics 365 FO environment, with a breakdown of the modules within this deployable package, including the Lasernet **Test and Performance Suite** module. Copyright information can also be found here. ![](https://cdn.document360.io/c831ef63-c6b3-48ee-b443-3e33644e4e2e/Images/Documentation/image (72)(3).png)