Documentation Index

Fetch the complete documentation index at: https://kb.lasernetgroup.com/llms.txt

Use this file to discover all available pages before exploring further.

Error Message: 'Query Filter Cannot Be Specified on a Query that Are Split into Multiple Queries Dues to 1:n Fetch Model'

Prev Next

When running a report, the following error may occur:

Error

Query filter cannot be specified on a query that are split into multiple queries dues to 1:n fetch mode.

This error message is also shown in Lasernet FO Connector 6 when configuring a query (within the Query group > Dialog setup > Default ranges and in Form links > Dialog setup > Default ranges).

It is similar to the following error message:

Error

1:N Fetch Mode is not allowed on Datasource having join condition with node other than its immediate parent.

The error occurs when adding a filter in the Query Wizard, Dialog Setup and/or the Default Ranges. The issue only occurs if the query contains two or more data source structures with at least one Fetch Mode/Fetch set to 1:N (One2Many).

The following is an example containing two data-source-structures:

A. Containing the data sources/tables CustTable and SalesTable.

B. Containing the data sources/tables CustTable, DlvTerm, and LanguageTxt.

Data source structure A:

Data source structure B:

Adding a filter in Lasernet FO Connector 6 would display the following error message:

Error

Query filter cannot be specified on a query that is split into multiple queries dues to 1:n fetch mode.

A similar error is shown in Lasernet FO Connector 5 when running the report.

Solution

There are three ways to resolve the issue, as follows:

Change the Query Structure

Restructure the query. It should be possible to have all the required data sources within the same data source structure as follows:

Having all data sources in the same structure would not cause the error when using 1:N in the Fetch Mode/Mode.

This approach also avoids the issue in relation to the row size when having a lot of data sources/tables (issue caused by 1:1).

Change 1:N to 1:1

Change 1:N to 1:1 in the Fetch Mode/Fetch, but this could cause the following error if many tables are joined together:

Error

[Microsoft][ODBC Driver 17 for SQL Server][SQL Server]Cannot create a row of size 8061 which is greater than the allowable maximum row size of 8060.

This error is only displayed if the query contains a lot of data sources/tables, and why Fetch Mode/Fetch 1:1 works in most cases.

Add a Range instead of a Filter (Lasernet FO Connector 6)

Lasernet FO Connector 6 contains the option to add a range instead of a filter by clearing the Filter checkbox in the Ranges in Dialog Setup, Ranges in the Form Links, and/or in the Ranges in the Query Wizard.

Clearing the Filter checkbox will fix the issue and enable multiple query structures with 1:N relationships in the Fetch Mode/Fetch.

Was this page helpful? Let us know at knowledgebase.feedback@lasernetgroup.com